How to choose a floor heating circulation pump

2026-01-10 15:25:24 mechanical

How to choose a floor heating circulation pump

With the advent of winter, the frequency of use of floor heating systems gradually increases. As one of the core components of the floor heating system, the choice of the floor heating circulation pump directly affects the heating effect and energy consumption of the floor heating. This article will combine the hot topics and hot content on the Internet in the past 10 days to give you a detailed introduction to how to choose a floor heating circulation pump.

1. The function of floor heating circulation pump

How to choose a floor heating circulation pump

The main function of the floor heating circulation pump is to promote the circulation of hot water in the floor heating pipes to ensure that the heat is evenly distributed to each room. An efficient floor heating circulation pump can improve heating efficiency, reduce energy consumption, and extend the service life of the floor heating system.

2. Key factors in choosing a floor heating circulation pump

When choosing a floor heating circulation pump, you need to consider the following key factors:

factorsDescription
trafficFlow refers to the amount of water that the circulation pump can deliver per hour, in cubic meters per hour (m³/h). The flow rate needs to be calculated based on the pipe length of the floor heating system and the area of ​​the room.
LiftThe head refers to the pipe resistance that the circulating pump can overcome, in meters (m). The lift needs to be determined based on the pipeline layout and height difference of the floor heating system.
PowerPower determines the energy consumption of the circulation pump, measured in watts (W). Too much or too little power will affect the system efficiency and needs to be selected according to actual needs.
noiseNoise is an important factor that affects the user experience. It is recommended to choose a circulating pump with a noise lower than 40 decibels.
Brand and after-salesChoose products from well-known brands to ensure quality and after-sales service.

3. Common types of floor heating circulation pumps

According to the working principle and structure, floor heating circulation pumps are mainly divided into the following two types:

TypeFeatures
Fixed frequency circulation pumpThe running speed is fixed and the price is low, but the energy consumption is high. It is suitable for users with small apartments or limited budgets.
Frequency conversion circulation pumpThe running speed is adjustable, the energy saving effect is significant, and the noise is low. It is suitable for large households or users with high comfort requirements.

4. How to calculate the required flow rate and head

In order to ensure that the selected floor heating circulation pump can meet the needs, it is necessary to calculate the flow rate and head of the system. Here is a simple calculation:

parametersCalculation formula
trafficFlow (m³/h) = total heat load of floor heating system (kW) / (water temperature difference (℃) × 1.163)
LiftLift (m) = total pipe resistance (Pa) / (density of water (kg/m³) × acceleration of gravity (m/s²))

5. Popular brand recommendations

According to the hot topics and user reviews on the Internet in the past 10 days, the following floor heating circulation pump brands have attracted much attention:

BrandFeatures
GrundfosDanish brand with high product quality, good energy saving effect and low noise.
WiloGerman brand, mature technology and perfect after-sales service.
New TerritoriesA well-known domestic brand with high cost performance and suitable for users with limited budget.

6. Installation and maintenance precautions

1.Installation location: The circulation pump should be installed on the return pipeline to avoid the impact of high temperature on the pump body.
2.Regular inspection: Regularly check the operating status of the circulation pump to ensure there is no abnormal noise or vibration.
3.Cleaning and maintenance: Clean the filter regularly to prevent impurities from clogging the pipes.

7. Summary

When choosing a floor heating circulation pump, you need to comprehensively consider factors such as flow, lift, power, noise, and brand after-sales service. Through scientific calculations and reasonable brand selection, you can ensure that the floor heating system operates efficiently and bring you a comfortable heating experience in winter.

Next article
  • What is an explosion-proof motor?Explosion-proof motors are motors specially designed for use in flammable and explosive environments. They can operate safely in high-risk industrial sites to avoid explosion accidents caused by sparks or high temperatures. This type of motor is widely used in industries such as petroleum, chemical industry, coal mines, natural gas, etc. where flammable gases, dust or steam exist. Thi
    2026-01-25 mechanical
  • What does cable ZB mean? Analysis of hot topics on the Internet in the past 10 daysRecently, the discussion about the meaning of "ZB" in cable models has become a hot topic in the industry, especially in the fields of electric power, construction and other fields. This article will combine the hot topic data of the entire network in the past 10 days to analyze in detail the definition, characteristics and application
    2026-01-23 mechanical
  • What is a glass electrode?Glass electrode is an electrochemical sensor widely used in chemical, biological and environmental detection. It is mainly used to measure the pH value or other ion concentration of the solution. Its core component is a sensitive membrane made of a special glass membrane that can respond to changes in the activity of hydrogen ions or other specific ions in the solution. The following will in
    2026-01-20 mechanical
  • What quota does dynamic environment monitoring cover?In recent years, with the rapid development of data centers, communication base stations and other facilities, the demand for dynamic environment monitoring systems (power environment monitoring systems) is increasing. When many companies purchase or deploy dynamic environmental monitoring systems, they often encounter the problem of "what quota to apply?" This art
    2026-01-18 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line